National laboratories around the world have long relied on the standard AC/DC resistors manufactured by Tinsley. Whether they’re used in thermometry or electrical applications—with AC or DC bridges—these resistors perform better than any other AC/DC resistors available.
View cart “Fluke 9142 – Field Metrology Wells” has been added to your cart.
Fluke 5430 Standard AC/DC Resistors
- Long-term stability better than 2 ppm/year (< 1 ppm typical)
- Traceable AC and DC calibrations available
- National lab design proven for more than 25 years
Categories: Fluke Calibration Equipment, Temperature Calibration
Related products
Fluke Calibration 1523 Single Channel Reference Thermometer
$2,820.00
Excluding GST 10%
Features
- Sensor types: PRTs, RTDs, thermistors, and thermocouples
- PRT Accuracy: up to ± 0.011 °C
- Thermocouple Accuracy: up to ± 0.24 °C
- Precision thermistor Accuracy: ± 0.002 °C
- Two models:
- 1523: Single channel standard model with memory for 25 readings
- 1524: Two channels; memory for logging 15,000 measurements
- 0.3 second typical sample interval
- Thermocouple types C, E, J, K, L, M, N, T, U, B, R, S
- Statistics: maximum, minimum, average, standard deviation
-10%
Close
Fluke 725 Multifunction Process Calibrator
Excluding GST 10%
Features
- Up to 30V and 24mA DC
- 0 to 3200Ω resistance
- Up to 10kHz frequency
- 1V peak-to-peak-minimum senitivity
- Combine with a 750P module for pressure
- Store frequently used test setups for later use
Fluke 787B Process Meter
Excluding GST 10%
Features
- 400mV up to 1000V voltage range
- Fluke connect
- 20 mA dc current source/measure/simulate
- Simultaneous mA and % of scale readout
- Frequency measurement up to 20 kHz
- Meets IEC 61010 CAT III and 600 V CAT IV standards
- Min/max/average/hold/relative modes
- Diode test and continuity beeper
- -4 to 131°F (-20 to 55°C) operating temp range
Fluke Calibration 1524 Dual Channel Reference Thermometer
$3,370.00
Excluding GST 10%
Features
- Sensor types: PRTs, RTDs, thermistors, and thermocouples
- PRT Accuracy: up to ± 0.011 °C
- Thermocouple Accuracy: up to ± 0.24 °C
- Precision thermistor Accuracy: ± 0.002 °C
- Two models:
- 1523: Single channel standard model with memory for 25 readings
- 1524: Two channels; memory for logging 15,000 measurements
- 0.3 second typical sample interval
- Thermocouple types C, E, J, K, L, M, N, T, U, B, R, S
- Statistics: maximum, minimum, average, standard deviation
Fluke 773 Milliamp Process Clamp Meter
Excluding GST 10%
Key features
- Loop calibrator that measures 4 to 20 mA signals without breaking the loop
- Features best in class 0.2% accuracy
- Sources 4 to 20 mA signals for testing control system I/O or I/Ps
- Delivers 0.01 mA resolution and sensitivity
- Measures DC voltage to verify 24V power supplies or voltage I/O signals
Fluke 705 Loop Calibrator
Excluding GST 10%
Key features
- Powerful loop calibrator that provides a very cost effective, integrated solution for calibration, repair, and maintenance of milliamp loops
- Provides simultaneous mA and % readout for quick, easy interpretation of readings.
- Delivers mA accuracy of 0.02%
- Features push button 25% steps for fast, easy linearity checks
Fluke 715 Volt/mA Loop Calibrator
Excluding GST 10%
Key features
- Compact, lightweight mA calibrator for measuring loop current (0-20 mA, 4-20 mA) signals
- Delivers very high accuracy—0.01%—and 1 mA resolution
- Measures voltage output process signals from PLCs and transmitters
- Sources or simulates 24 mA loop current
- Sources voltage to 100 mV or 10V
- Provides typical 18 hour battery life
-10%
Close
Fluke 700HTPK Hydraulic Test Kit
Excluding GST 10%
The Fluke-700HTPK Hydraulic Test Kit
- Combine with any Fluke-700G Series Gauge, 1,000 psi range or greater, to make a complete pressure testing kit
- Generate pressure up to 10,000 psi, 690 bar with the included 700HTP-2 test pump
- Connect the 700G Series gauge directly to the HTP-2 hand pump
- Includes 700HTH-1 hose kit and adapters for connecting to the pressure device to be tested
- Hard case protects pump and gauge and allows gauge to remain connected to the pump