 Micro-Bath |
|
|
|
| Model |
Range |
Accuracy |
Description/Features |
| 6102 |
35 °C to 200 °C 95 °F to 392 °F |
±0.25 °C |
World’s smallest calibration bath. Stability to ±0.02 °C. Stirred 2.5-inch-diameter tank. |
| |
|
|
| 7102 |
–5 °C to 125 °C 23 °F to 257 °F |
±0.25 °C |
Portable bath to –5 °C. No refrigeration—solid-state cooling. Stability to ±0.015 °C. |
| |
|
|
| 7103 |
–30 °C to 125 °C –22 °F to 257 °F |
±0.25 °C |
Ultracold Micro-Bath reaches –30 °C. No refrigeration or external cooling needed. Stability to ±0.03 °C |
|
|
|
|
 Handheld |
|
|
|
|
| Model |
Range |
Accuracy |
Description/Features |
| 9100S |
35 °C to 375 °C 95 °F to 707 °F |
±0.25 °C at 100 °C ±0.5 °C at 375 °C |
World’s smallest dry-well. Fixed block with 4-inch well depth. Four hole patterns available. |
|
|
|
|
| 9102S |
–10 °C to 122 °C 14 °F to 252 °F |
±0.25 °C |
Handheld unit cools to –10 °C. Two 0.5-inch-diameter, removable sleeves. |
|
|
|
|
|
 Field Dry-Well |
|
|
|
|
| Model |
Range |
Accuracy |
Description/Features |
| 9009 |
–15 °C to 350 °C 5 °F to 662 °F |
Cold block: ±0.2 °C Hot block: ±0.6 °C |
Dual-block industrial dry-well. Each block has two wells with removable sleeves. Water- and air-tight enclosure. |
| |
|
|
|
| 9103 |
–25 °C to 140 °C –13 °F to 284 °F |
±0.25 °C |
Small, lightweight field calibrator reaches –25 °C. Stability to ±0.02 °C. Calibrates up to six probes at once. |
| 9140 |
35 °C to 350 °C 95 °F to 662 °F |
±0.5 °C |
Portable field calibrator. Choose from four multi-hole, removable inserts. |
| 9141 |
50 °C to 650 °C 122 °F to 1202 °F |
±0.5 °C to 400 °C ±1 °C to 650 °C |
High-temp field calibrator. Interface-it software and RS-232 included. Extremely small and fast for temperature range |
| 3125 |
35 °C to 400 °C 95 °F to 752 °F |
±0.5 °C to 200 °C ±1.0 °C to 400 °C |
Calibrates surface sensors. Plate stability of ±0.3 °C. |
|
|
|
|
|
 Infrared Calibrators |
|
|
|
|
| Model |
Range |
Accuracy |
Description/Features |
| 9132 |
50 °C to 500 °C 122 °F to 932 °F |
±0.5 °C at 100 °C ±0.8 °C at 500 °C |
Certifies most handheld pyrometers. Short heating and cooling times. |
| |
|
|
| 9133 |
–30 °C to 150 °C –22 °F to 302 °F |
±0.4 °C |
Calibrates at cold temperatures. Gets to desired temperature quickly. |
| 9135 |
50 °C, 100 °C, 150 °C 122 °F, 212 °F, 302 °F |
±1 °C |
Easiest to use IR calibrator. Three set-points—all reached quickly. |
|
|
| |
|
|
Zero Point Dry-Well |
|
 |
| |
|
| Model |
Range |
Stability |
Description/Features |
| 9101 |
0 °C 32 °F |
±0.05 °C |
Solid-state cooling. Replaces messy ice baths—easy to operate. Three wells, each 6 inches deep. |
|
|
| |
|
|
Dual Block Dry-Well |
|
 |
| |
|
| Model |
Range |
Stability |
Description/Features |
| 9011 |
50 °C to 670 °C 122 °F to 1238 °F |
±0.15 °C at 100 °C ±0.65 °C at 600 °C |
Combined ranges from –30 °C to 670 °C. 1 unit – 2 blocks. Two independent temperature controllers (hot and cold side). Stability: ±0.01 °C. |
| |
|
|
|
| Cold Block |
–30 °C to 140 °C –22 °F to 284 °F |
±0.25 °C (insert wells) ±0.65 °c (fixed wells) |
Multi-hole inserts hold up to 8 probes at once. |
|
|
| |
|
|
Portable Lab Dry-Wells |
|
 |
| |
|
| Model |
Range |
Stability |
Description/Features |
| 9007 |
–40 °C to 140 °C –40 °F to 284 °F |
±0.15 °C |
–40 °C with solid-state Peltier cooling. Rugged truck-, plane-, and sea-worthy enclosure. |
|
|
| |
|
|
Furnaces |
|


|
| |
|
| Model |
Range |
Stability |
Description/Features |
| 9150 Thermocouple Furnace |
150 °C to 1200 °C 302 °F to 2192 °F |
±0.5 °C |
Benchtop thermocouple furnace. Interchangeable insert sleeves. Fast heating and cooling. |
| 9112B Calibration Furnace |
300 °C to 1100 °C 572 °F to 2012 °F |
±0.1 °C |
Standard block fits five probes. Accommodates long probes. Gradients less than ±0.3 °C at 1000 °C. |
|
|